Nevermore SOPs

From MITNA
Revision as of 23:55, 7 October 2007 by ThomS (Talk | contribs)

Jump to: navigation, search

This is a list of miscellaneous operational lore for Nevermore.

  • engine
    • from a cold start, glow for 10 seconds before starting the engine.
    • from a cold start, let the engine idle for 5 minutes before revving it up.
    • the engine runs best (least wear, most efficiency) at around 2000 rpm.
  • head
    • there are two thru-hull valves for the head. one is to let seawater in (yellow handle), the other is to let sewage out (rusty wrench handle).
    • there is a valve with blue handle that determines whether sewage goes overboard or into the holding tank.
    • to check the level of the holding tank, visually inspect it. the holding tank is located on the port side of the v berth. do not attempt to open/remove the clear plastic inspection portal.
  • electrical
    • batteries
      • never have ALL batteries OFF when engine is running (pops alternator diodes)
      • generally, have only one battery ON at a time, especially when engine isn't running
      • might set upper switch to BOTH with engine running if both batteries are equally discharged
    • use the guppy when the boat is at anchor or moored. when the guppy is in the water, the guppy corrodes instead of the copper wires on the boat.
  • freshwater
    • if you must remove a large volume of water from the freshwater tanks, do it through an inspection portal using a hand pump.